Operation Selection At External Operator Disconnection; Initial Screen Selection (Initial Screen After Power-On); Initial Screen Automatic Return Function - Omron MX2 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

7-6-4

Operation Selection at External Operator Disconnection

If the Inverter detects a disconnection (interruption of communications for 5 seconds or longer) with the
optional Digital Operator (Model: 3G3AX-OP01), the operation of the Inverter depends on the Opera-
tion Selection at External Operator Disconnection (b165) setting.
Parameter
Function name
No.
Operation Selection at
b165
External Operator Dis-
connection
7-6-5

Initial Screen Selection (Initial Screen after Power-on)

Use this parameter to select from the following the screen that appears on the Digital Operator at
power-ON. (By factory default, this is set to 001 (d001).)
Parameter
Function
No.
Initial Screen
b038
Selection
*1. If you select 000 and turn off the power supply, the inverter will display this parameter (b038) at the next pow-
er-on.
7-6-6

Initial Screen Automatic Return Function

To enable this function, set the Initial Screen Automatic Return Function (b164) to 01 (Enabled).
When enabled, the function will automatically switch the display to the initial screen if the Digital Opera-
tor is not operated for 10 minutes.
Parameter
Function name
No.
Initial Screen Auto-
b164
matic Return Function
Multi-function Compact Inverter 3G3MX2-EV2 User's Manual (I666-E1)
00:
Trip (E40.)
01:
Trip after deceleration stop (E40.)
02:
Ignore
03:
Free-run stop
04:
Deceleration stop
Data
Content of display (Digital Operator)
name
Screen on which the Enter key was last pressed
000
(Parameters except for d*** and F001)
001
d001 (Output Frequency Monitor)
002
d002 (Output Current Monitor)
003
d003 (RUN Direction Monitor)
:
: (Each data corresponds with d***.)
060
d060 (Inverter Mode Monitor)
201
F001 (Output Frequency Setting/Monitor)
202
Do not set.
00:
Disabled (Automatic return disabled)
01:
Enabled (Automatic return enabled)
Data
*1
Data
7 Other Functions
Default
Unit
data
02
Default
Unit
data
001
Default
Unit
data
00
7 - 57