Restoring Factory Settings - Omron SPINOGY 3G3MX2 Quick Start Manual

Table of Contents

Advertisement

05.2

Restoring factory settings

The MX2 frequency inverter can be reset to the original factory/default settings. To initialize the inverter, follow
the steps below.
01. Select initialization mode in b084.
02. If b084 = 02, 03 or 04, select initialization target data in b094.
03. If b084 = 02, 03 or 04, select country code in b085.
04. Set 01 in b180.
05. After successful initialization, the display jumps to d001.
Func. code
Name
Initialization
b084
selection
Initialization target
b094
data
Initialization
b085
parameter selection
b180
Initialize trigger
06 Troubleshooting
Description
Select initialized data, five option codes:
• 00 no (Clears the trip monitor)
• 01 Trip data (Initializes data)
• 02 Parameters (Clears the trip monitor and
initializes data)
• 03 Trip+Param (Clears the trip monitor and
parameters)
• 04 Trp+Prm+EzSQ (Clears the trip monitor,
parameters and Drive program)
Select initialized parameters, four option codes:
• 00 All
• 01 All parameters with the exception of input/
output terminals and communication
• 02 Only parameters registered in U***
• 03 All parameters except those registered in
U*** and b037
Select initial data for initialization:
• 00 JPN
• 01 EUR
This is to perform initialization by parameter input
with b084, b085 and b094.
Two option codes:
00 No action
01 Initialize
23

Advertisement

Table of Contents
loading