If the median value of the measured nip is toward the
higher limit of the standard, tighten the screw on the
side with a higher nip value at the edge.
If the nip needs adjustment while the nip balance is
correct, the adjusting screw both at the front and rear
may be given a 1/2 turn so that the nip may change by
about 0.3 mm.
F-11-168
Service Mode
COPIER>FUNCTION>FIXING>NIP-CHK
Use it to generate output for fixing nip width auto
measurement.

11.5.11 Delivery Upper Guide

11.5.11.1 Removing the Fixing
Unit
1) Slide out the fixing/feeding unit.
2) Remove the 2 screws [1], and detach the fixing unit
[2].
11.5.11.2
Delivery Upper Guide
1) Remove the insulating cover fixing plate [1]. (3
snap-on claws)
2) Remove the insulating cover [1].
0000-5033
3) Remove the rear cover [1]. (2 snap-on claws)
Chapter 11
F-11-169
Removing
the
F-11-170
F-11-171
0000-5034
11-51