Chapter 16
16.3.10.58 E504 Error code detail There is a fault in stack size detection.
Symptom
E504 There is a fault in stack size detection. (Error code detail)
Description
Detail
0001
0002
0003
0004
16.3.10.59 E505 Error code detail There is a fault in the backup RAM.
Symptom
E505 There is a fault in the backup RAM. (Error code detail)
Description
Detail
0001
16-148
Description
The height sensor (PS1) is
faulty.
The height sensor (PS1) is
faulty.
The connector of the height
sensor (PS1) is faulty.
The DIP switch for the
height sensor (PS1) is not
adjusted correctly.
Description
The checksum value of the finisher controller
PCB is faulty.
T-16-23
Timing of detection
The communication between the height
sensor and the finisher controller PCB is
prevented. Or, there is a fault in the
communication data.
The communication between the height
sensor and the finisher controller PCB is
prevented for 0.1 sec or more.
This fault is detected at power-on.
There is a fault in the adjustment of the
sensor by the DIP switch.
T-16-24
Timing of detection
This fault is detected at
power-on.
0002-1675
0002-1677