Chapter 16
16.3.4.4.14 iRC3200 reboots repeatedly after FAX board is installed
[ Inspected by Canon Inc. ]
< Field Remedy >
As a result of inspection, it was found that this symptom occurred because the Main Controller PCB (Sub) was
faulty. If this symptom does not recur without it, replace the Main Controller PCB (Sub) with a new one.
Main Controller PCB (Sub): FG3-2855
16.3.4.4.15 iRC3200 locks up while displaying 'Copying' even when pressing Start key
[ Case in the field ]
< Field Remedy >
As a result of inspection, it was found that the Interface PCB was faulty. Unplug and reinsert the connectors on
it. If the symptom still recurs, replace it with a new one.
Interface PCB: FM2-0036
16.3.4.4.16 iRC3200 shuts down and reboots unintentionally during FAX transmission
[ Case in the field ]
Field Remedy
In the field, this symptom occurred because the Resolution Switch PCB was faulty. Remove and install it once
again. If the symptom still recurs, replace it with a new one.
Resolution Switch PCB: FG3-2728
16.3.4.4.17 iRC3200 reboots unintentionally: USB Interface Board is installed
[ Case in the field ]
Field Remedy
In the field, this symptom occurred because the USB interface board was faulty. Install the board once again.
If the symptom still recurs, replace it with a new one.
(Note that the USB interface board is not assigned as a service part.)
16.3.4.4.18 When making copy, iRC3200 goes back to ready state and fails to output paper after
scanning: FAX Board is installed
[ Case in the field ]
Field Remedy
In this case, this symptom did not occur without the original FAX board but recurred when installing other FAX
board. It was found in the field that the DC fuse PCB was faulty. Unplug and reinsert the connectors on the
DC fuse PCB. If the symptom still recurs, replace the PCB with a new one.
DC Fuse PCB: FG3-2337
16.3.4.4.19 iRC3220 reboots when progress bar reaches right end and it almost starts up following
power-on upon installation
[ Inspected by Canon Inc. ]
Description
The captioned symptom occurred because the connector J308 on the Reader Controller PCB in the reader unit.
16-76
0005-6103
0005-6122
0005-6160
0005-6161
0005-6163
0008-1577