E711 Error Code Detail There Is A Fault In Ipc Communication - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

Chapter 16
16.3.10.101
E711
communication.(DADF-K1)
Symptom
E711 There is a fault in IPC communication.(DADF-K1)(Error code detail)
Description
Detail
0001
0002

16.3.10.102 E711 Error code detail There is a fault in IPC communication.

Symptom
E711 There is a fault in IPC communication. (Error code detail)
Description
Detail
0001
16-170
Error
code
detail
Description
There is a fault in data communication.
The ADF controller or the reader
controller PCB is faulty. The connector
between the reader unit and the ADF has
poor connection.
There is a fault in data communication.
The finisher controller, pedestal
controller, or DC controller PCB is
faulty. The connector between the
finisher and the cassette pedestal has
poor contact.
Description
There is a fault in data communication.
The ADF controller or the reader
controller PCB is faulty. The connector
between the reader unit and the DADF
has poor contact.
There
is
T-16-53
Timing of detection
An error has been detected 4
times or more within 1.5 sec
after the communication
between the reader unit and the
ADF has been disrupted.
An error has been detected 4
times or more within 1.5 sec
after the communication
between the finisher and the
machine has been disrupted.
T-16-54
Timing of detection
An error has been detected 4
times or more for 1.5 sec after
the communication is disrupted
between the reader unit and the
DADF.
a
fault
in
IPC
0002-1787
0002-1789

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir c3220n prt

Table of Contents