Chapter 16
Field Remedy
DC Power Supply PCB Part No. FG6-8970-000 (100/120V), FG6-8971-000 (220/240V)
16.3.4.1.4 PS-C1: Not start up while 'Please Wait' keeps displaying. iRC3200 Ver.9.05, PS-C1
Ver1.1.1
[ Verified by Canon Inc. ]
< Field Remedy >
Shut down the power of PS-C1 and iRC3200, and unplug the LAN cable connecting to network. Then, turn ON
the power of both devices.
a. If PS-C1 starts up normally
It is possible that the IP address for communication between PS-C1 and the user's LAN environment and the
one for communication between PS-C1 and iRC3200 might be identical. Download the patch file (1-
7RJ592.ps) into PS-C1 for a solution against overlap of IP addresses.
b. If PS-C1 does not start up normally while 'Please Wait' keeps displaying
Reinstall the system of PS-C1 Ver.1.1.1 again. If the patch file (1-7RJ592.ps) has already been downloaded,
follow the steps below:
1. After reinstalling the System of PS-C1 Ver.1.1.1, shut down the power of PS-C1.
2. On iRC3200, in service mode [COPIER> Option> INT-FACE> IMG-CONT], set at [0]. Then, shut down
and turn on the power of iRC3200.
3. On iRC3200, in service mode [COPIER> Option> INT-FACE> IMG-CONT], se at [3]. Then, shut down the
power of iRC3200.
4. Turn on the power of PS-C1 and then iRC3200. After making sure that the both devices start up normally,
download the patch file (1-7RJ592.ps) into PS-C1.
16.3.4.1.5 DADF-K1: iRC3200 does not start up while progress bar is stopping halfway, with
DADF-K1 installed
[ Inspected by Canon Inc. ]
< Field Remedy >
As a result of inspection, it was found that the Interface PCB was faulty. Unplug and reinsert the connectors on
it. If the symptom still recurs, replace it with a new one.
Interface PCB: FM2-0036

16.3.4.2 Control Panel-Related

16.3.4.2.1 iRC3200 does not start up: After indication of message 'Starting up. Wait a moment.',
LCD alternates between black and blue
[ Case in the field ]
Cause
Due to faulty soldering of J1204 (for the Ethernet board) on the Main Controller PCB, a problem occurs with the
LCD during a power-on communication checking.