9.4 Image Stabilization Control
9.4.1 Outline of Image Quality Control
Changes in temperature/humidity or passage of time can cause the machine to produce images of varying quality. To
ensure that the quality of images remain stable, the levels of voltage outputs and volumes of toner supply are
corrected:
So that the machine's image
reproduction remains stable, the
following control mechanisms are
used:
ATR Control
Discharge Current Level Control
ATVC Control
PASCAL Control/SALT Control
9.4.2 Automatic Image Stabilization Control
Operation
Power-on/
jam
recovery
Discharge
ATVC
ATR
current
control
control
level
control
- if fixing roller surface temperature >= 100 deg C
YES
YES
NO
- if fixing roller surface temperature < 100 deg C
YES
YES
YES
T-9-17
to suit changes in toner density/toner
consumption
to prevent faulty images in a high humidity
environment
(correction of charging AC bias)
to ensure good transfer
(correction of transfer bias level)
to suit changes in image density and gradation
(correction of charging/developing/transfer bias;
correction of image correction table)
T-9-18
SALT-
Image
Dmax
position
control
correction
NO
YES
YES
YES
Chapter 9
0000-4486
0000-4487
SALT-
Estimated
Dhalf
duration
control
(sec)
NO
about 80 *6
YES
about 240
*7
9-13