8.3 Various Control
8.3.1 Controlling the Laser Activation Timing
8.3.1.1 Turning On/Off the Laser
The laser light is turned on/off in keeping with combinations of control signals (TRL0/1/2) from the DC controller
PCB.
CTR
L2
0
0
0
0
1
1
1
1
CTR
CTR
Status of laser A
L1
L0
0
0
OFF
0
1
OFF
(bias current applied)
1
0
APC control
1
1
OFF
(bias current applied)
0
0
ON
(for factory adjustment)
0
1
OFF
(bias current applied)
1
0
ON
(for factory adjustment)
1
1
ON
(for image formation)
T-8-6
Status of laser B
OFF
APC control
OIFF
(bias current applied)
OFF
(bias current applied)
ON
(for factory adjustment)
ON
(for factory adjustment)
OFF
(bias current applied)
ON
(for image formation)
Chapter 8
0000-4456
8-5