Code
E351
E402
17-8
Detail
Description
0008
000e
0010
0025
0028
0034
0036
The ECO-ID PCB is faulty.
0000
There is a fault in the feeder motor.
Timing of detection
The ASIC (used for compression/
expansion processing) on the image
conversion board is faulty.
While encoding is under way, a
time-out condition occurs (i.e.,
there is no response within 30 sec).
The data is damaged, there is a
memory error on the HD.
The ASIC (used for compression/
expansion) on the image conversion
board is faulty.
While decoding is under way, a
time-out condition occurs.
The ASIC (used for compression/
expansion) on the image conversion
board is faulty.
While rotation processing is under
way, an image data transfer error
occurs.
The ASIC (used for compression/
expansion) on the image conversion
board is faulty.
While rotation processing is under
way, a time-out condition occurs.
The ASIC (used for enlargement/
reduction) on the image conversion
board is faulty.
While enlargement/reduction
processing is under way, an image
data transfer error occurs.
The ASIC (used for enlargement/
reduction) on the image conversion
board is faulty.
While enlargement/reduction
processing is under way, a time-out
condition occurs.
There is a fault in the initial
communication.