17.1 Error Code Details
17.1.1 Error Code Details Table
Code
E000
E001
E002
Detail
Description
The rise in temperature in the fixing unit at time of power-on is inadequate.
0001
The fixing unit is overheating.
0001
0003
0004
0005
The rise in temperature of the fixing unit is inadequate.
0002
0003
T-17-1
Timing of detection
After power-on, the output of the
noncontact thermistor does not
reach 40 deg C within 180 sec.
The high-temperature detection
port continues to remain ON for
500 msec.
The reading of the no-contact
thermistor remains 250 deg C for
500 msec.
The difference in temperature
between the non-contact thermistor
and the end thermistor remains 80
deg C or more for 500 msec.
At the end of initial rotation, the
difference in temperature between
the sub (end) thermistor and the
main (non-contact) thermistor is 20
deg C or more for 100 msec.
(A reversal in temperature (caused,
for example, by a piece of residual
paper) is detected.)
The output of the non-contact
thermistor does not reach 60 deg C
within 240 sec after it has reached
40 deg C.
The output of the non-contact
thermistor does not reach 90 deg C
within 180 sec after it has reached
60 deg C.
Chapter 17
0006-4868
17-1