F-10-125
3) Remove the bushing [1] at the rear.
F-10-126
4) Remove the resin clamp [1], and pull out the
manual feed roller [2].
When attaching the manual feed roller, be sure that the
groove of the parallel pin is toward the rear.
F-10-127
When attaching the bushing and the gear at the front,
check to be sure that the claw is hooked on the groove
of the roller.
F-10-128
10.10.15.5
Removing
Manual
Feed
Roller
1)
Take care not to lose the spring found at the front
when detaching the face plate.