16.3.10.86 E602-0001 Error code At about 5 sec. after the power is turned ON,
due to a failure of the Distribution Board PCB Ass'y
Symptom
About 5 sec. after the power is turned ON, E602-0001 is displayed due to a failure of the Distribution Board
PCB Ass'y.
Cause
Distribution board failure
Items to Check
1) Check whether 12V DC is input to the HDD unit J44-1 and 5V to J44-4. If no, check whether 12V DC is
output from the distribution board PCB J1505-1 and 5V from J1505-4.
If there is DC output from the distribution board PCB J1505, check the connection of the flat cable between the
HDD and the main controller. If there is no problem there, the HDD is likely faulty.
2) If there is no DC output from the distribution board PCB J1505, check whether 5V is input to the distribution
board PCB J1501-1 and 12V to J1501-8. If no, check the fuse PCB.
Field Remedy
Replace the distribution board PCB Ass'y.
Distribution Board PCB Ass'y Part No. FG6-9676-000
16.3.10.87 E602-0001 Error code At about 5 sec. after the power is turned ON,
due to a connection failure of the flat cable between the HDD unit and the main
controller
Symptom
About 5 sec. after the power is turned ON, E602-0001is displayed due to a connection failure of the flat cable
between the HDD unit and the main controller.
Cause
Faulty connection of the flat cable between the HDD unit and the main controller
Items to Check
Check whether 5V DC is supplied to J44-1 and 12V to J44-4 on the HDD unit.
If No, the distribution board PCB Ass'y or the DC power supply PCB Ass'y.
Field Remedy
Securely insert the flat cable between the HDD unit and the main controller.
Chapter 16
0002-2029
0002-2486
16-165