16.3.10.3 E002 Error code detail The rise in temperature of the fixing unit is
inadequate.
Symptom
E002 The rise in temperature of the fixing unit is inadequate. (Error code detail)
Description
Detail
0002
0003
0004
0005
0006
0007
0101
0102
16-122
Description
The output of the non-contact thermistor does not reach
60°C within 240 sec after it has reached 40°C.
The output of the non-contact thermistor does not reach
90°C within 180 sec after it has reached 60°C.
The output of the non-contact thermistor does not reach
120°C within 240 sec after it has reached 90°C.
The output of the non-contact thermistor does not reach
140°C within 180 sec after it has reached 120°C.
The output of the non-contact thermistor does not reach
160°C within 180 sec after it has reached 140°C.
The output of the non-contact thermistor does not reach
180°C within 180 sec after it has reached 160°C.
The output of the non-contact thermistor does not reach
120°C within 300 sec after power-on.
The output of the non-contact thermistor does not reach
190°C within 300 sec after it has reached 120°C.
T-16-4