Chapter 10
F-10-433
10.10.43.4
Removing
Delivery Vertical Path Unit
(New)
For the new delivery vertical path unit to function, the
version of the DC controller must be 3.06 or later. Be
sure to check its version in service mode:
COPIER>DISPLAY>VERSION>D-CON.
1) Slide out the fixing/feeding unit.
2) Open the delivery vertical path cover [1]; then,
remove the 2 screws [2], and detach the upper left
cover [3].
F-10-434
3) Remove the screw [1], and detach the delivery
10-130
the
0006-8960
inside cover [2]; then, detach the delivery vertical
path cover [3] from the machine.
F-10-435
4)
To detach the delivery vertical path unit, lift the unit
and then pull it out toward the front.
Disconnect the 2 concoctors [1], and remove the 4
screws [2]; then, detach the delivery path unit [3].
(The delivery path unit will no longer be used.)
F-10-436
5) Using a flat-blade screwdriver, detach the slip-stop [2]
from the delivery vertical path cover [1]; then, detach
the strap [3] from the delivery inside cover. (The
delivery vertical path cover will no longer be used.)