E580 Error Code Detail There Is A Fault In Ascent/Descent Of The Stack Tray - Canon iR C3200 Series Service Manual

Hide thumbs Also See for iR C3200 Series:
Table of Contents

Advertisement

16.3.10.72 E580 Error code detail There is a fault in ascent/descent of the stack
tray.
Symptom
E580 There is a fault in ascent/descent of the stack tray. (Error code detail)
Description
Detail
16.3.10.73 E584 Error code detail There is a fault in feed operation (No. 2).
Symptom
E584 There is a fault in feed operation (No. 2). (Error code detail)
Description
Detail
0001
0002
0003
Description
The stack tray ascent/descent
motor (M5), stack tray paper
height sensor (S10), or the stack
tray ascent/descent motor clock
sensor (S9) is faulty. The
connector is disconnected. An
excess load is imposed on the
stack tray ascent/descent motor.
Description
The No. 2 feed motor (M8)
or the shutter open sensor
(PI5) is faulty.
The No 2 feed motor (M8) or
the shutter closed switch
(MS4) is faulty.
The safety area detecting
switch (MS3) or the shutter
closed switch (MS4) is
faulty.
T-16-37
Timing of detection
The stack tray upper limit sensor goes
ON while the stack tray ascent/descent
motor is in operation, or the clock pulse
of the stack tray direction motor clock
sensor is not detected 15 times or more
within 0.8 sec.
The stack tray does not reach the stack
tray height sensor within 4 sec after the
stack tray ascent/descent motor has
started ascent operation.
T-16-38
Timing of detection
The shutter open sensor does not go ON
when the No. 2 feed motor has been rotated
in reverse for 1 sec or more.
The shutter closed switch does not go ON
when the No. 2 feed motor has been rotated
in reverse for 1 sec or more.
The shutter closed switch is OFF when the
tray 1/2 is in the OFF position of the safety
area switch while the tray ascent/ descent
motor is in operation.
Chapter 16
0002-1716
0002-1718
16-155

Hide quick links: