NVRAM Data Upload (SP5-824)

[A]
1. Turn off the main switch.
2. Remove the application cover [A] (1 screw).
3. Plug the flash memory card [B] into the card slot.
NOTE: Make sure that the surface printed "A" faces the rear side of the
machine (as viewed from the front of the machine).
4. Turn on the main switch.
5. Access SP mode 5-824.
6. The machine erases the current settings, then writes the machine's settings to
the flash memory card. This takes about 60 seconds. If uploading failed, an
error message appears (see "Program Download"). At this time, repeat the
upload procedure.
7. Turn off the main switch, then remove the IC card.
SM
CÓPIA NÃO CONTROLADA
A265M514.WMF
4-75
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
A265M500.WMF
A265/A267
[B]

Advertisement