Scanner Switch 0F
No
FUNCTION
0
Image rotation before
transmission (A4/LT
sideways)
0: Disabled
1: Enabled
1
Not used
2
Image rotation before
transmission (A5/HLT
lengthwise)
0: Disabled
1: Enabled
3-7 Not used
SM
CÓPIA NÃO CONTROLADA
This bit determines whether the machine rotates
the scanned image by 90 degrees before
transmission.
If this bit is set at 1, A4 (LT) sideways images
(297 mm width in the protocol) will be transmitted
as A4 (LT) lengthwise images (216 mm width in
the protocol).
Refer to Image Rotation Before Transmission in
section 2 for more details.
Do not change the setting.
This bit determines whether the machine rotates
the scanned image by 90 degrees before
transmission.
If this bit is set at "1", A5 (HLT) lengthwise images
will be transmitted as A4 (LT) width images (216
mm width in the protocol).
Refer to Image Rotation Before Transmission in
section 2 for more details.
Do not change the setting.
4-35
CÓPIA NÃO CONTROLADA
BIT SWITCHES
COMMENTS