Gestetner A265 Service Manual page 194

Table of Contents

Advertisement

SERVICE PROGRAM MODE
Mode No.
Class
Class
1 and 2
3
Paper Feed Timing
(2nd, 3rd, 4th Paper
2
Feed, LCT, and By-
pass Feed)
1-003*
Paper Feed Timing
(Duplex)
3
By-pass Paper Size
1-007
Display
Fusing Temperature
1
Adjustment
(Stand-by)
Fusing Temperature
Adjustment
2
(Low Power
1-105*
Level 2)
Fusing Temperature
Adjustment
3
(Special Paper)
Fusing Temp.
Display
1-106
Fusing Soft Start
Adjustment
(Stand-by, Energy
saver)
1
1-107*
Fusing Soft Start
Adjustment
(Printing)
2
Fusing Soft Start
Setting
(Stand-by, Energy
saver)
1-108*
1
A265/A267
CÓPIA NÃO CONTROLADA
Adjusts the paper feed clutch timing at
registration. The paper feed clutch timing
determines the amount of paper buckle at
registration. (A larger setting leads to more
buckling.)
Displays the by-pass paper width sensor
output.
Adjusts the fusing temperature for standby
mode.
Adjusts the fusing temperature for low
power level 2.
With a lower value, the machine takes more
time to reach the ready condition.
Adjusts the additional fusing temperature for
the special paper mode selected by the
lever on the 2nd paper tray; also for the
bypass tray (all paper types).
Displays the fusing temperature.
Press the " (Clear Modes) key to exit the
display.
Adjusts the number of zero-cross cycles of
the fusing lamp ac supply needed for the
fusing lamp power to reach 100%. Use a
higher number if the customer complains
about sudden power dropouts.
For European models, this SP mode is
effective in the stand-by mode and
energy saver mode only.
See "Detailed Descriptions - Fusing Unit" for
details on SP1-107, Section 2.10.6.
For European models only.
Adjusts the number of zero-cross cycles of
the fusing lamp ac supply needed for the
fusing lamp power to reach 100% when
raising the temperature during printing. Use
a higher number if the customer complains
about sudden power dropouts.
See "Detailed Descriptions - Fusing Unit" for
details on SP1-107, Section 2.10.6.
Selects whether the fusing temperature
control cycle is 1 or 3 seconds.
For European models, this SP mode is
effective in the stand-by mode and
energy saver mode only.
If this is "1", the power supply fluctuates less
when the fusing lamp turns on. See
"Detailed Descriptions - Fusing Unit" for
details, Section 2.10.6.
4-6
CÓPIA NÃO CONTROLADA
Function
Settings
0 ~ 10
1 mm/step
5 mm
0 ~ 20
1 mm/step
6 mm
155 ~ 190
1°C/step
170°C
0 ~ 80
1°C/step
80°C
0 ~ 20
1°C/step
10°C
N. America
0: 3 times
1: 10 times
2: 20 times
Europe/Asia
0: 5 times
1: 10 times
2: 20 times
0: 5 times
1: 10 times
2: 20 times
0: 1 sec
1: 3 sec
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267

Table of Contents