TRANSFER UNIT

6.4.2 IMAGE DENSITY SENSOR

1. Open the right cover [A].
2. Remove the unit band [B].
3. Remove the right cover [A] (1 connector),
4. Remove the sub right cover [C] (2 hooks).
5. Replace the image density sensor [D] (1 connector).
6. Reset the ID sensor error counter (SP 7-912).
A265/A267
CÓPIA NÃO CONTROLADA
[B]
A267R201.WMF
6-16
CÓPIA NÃO CONTROLADA
[A]
[C]
A267R202.WMF
[D]
SM