1. Remove the rear cover [A] (4 screws), and cut away the small cover [B].
2. Disconnect the cables [C] and [D], then remove the fax unit [E] (6 screws).
3. Connect the cable [F] to the DIU board [G].
4. Attach the DIU board [G] to the bracket [H] (2 screws/2 hexagonal screws).
5. Connect the cable [I] to CN609 on the FCU board, then re-install the fax unit [J]
in the machine.
6. Attach the DIU assembly [K] to the machine (2 screws), then connect the cable
[I] to the DIU assembly [K] and run the cable [I] through the clamp [L].
7. Re-install the rear cover (4 screws).
8. Plug in the machine and turn on the main power and operation switches.
9. Enter SP mode as follows:
1) Press the "Clear Modes" key.
2) Enter "107"
3) Press the "Clear/Stop" key for more than 3 seconds.
" → # → $ → % → &
10. Enter "2" (select "Fax").
11. Enter "01" (select "Bit Switches").
12. Enter "1" (select "System Switch").
13. Press the "↑ Switch" key several times and select "Switch 1C".
14. Enter "0" and change bit 0 from 0 to 1.
15. Exit SP mode and turn the main switch off/on.
16. Print the system parameter list. If "TR29" appears in the "option" section of the
system parameter list, go ahead. Otherwise, check the cable connection.
17. Follow the instructions in the operator's manual for how to connect the machine
to a host computer and how to set up the machine and computer, if required.
NOTE: 1) A "straight-through" shielded serial cable is required, but it is not
enclosed.
2) One end of the serial cable must have a DB25 male connection to
connect to the DIU.