BIT SWITCHES
Communication Switch 17
No
FUNCTION
0
SEP reception
0: Disabled
1: Enabled
1
SUB reception
0: Disabled
1: Enabled
2-7 Not used
Communication Switch 18
No
FUNCTION
0
Memory Lock for PSTN-1
0: Disabled
1: Enabled
1
Memory Lock for PSTN-2
0: Disabled
1: Enabled
2
Memory Lock for ISDN
0: Disabled
1: Enabled
3-7 Not used
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B - Not used (do not change the settings)
Communication Switch 1C - Not used (do not change the settings)
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E
No
FUNCTION
0
Extension access code (0 to
to
7) to turn V.8 protocol On/Off
7
0: On
1: Off
A265/A267
CÓPIA NÃO CONTROLADA
0: Polling transmission to another maker's
machine using the SEP (Selective Polling) signal
is disabled.
0: Confidential reception to another maker's
machine using the SUB (Sub-address) signal is
disabled.
Do not change the settings.
Change this bit to 1 when the customer requires.
Change this bit to 1 when the customer requires.
This function requires an optional G3 unit.
Change this bit to 1 when the customer requires.
This function requires an optional G4 unit.
Do not change the settings.
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to "1" to disable V.8.
Example: If "0" is the PSTN access code, set bit
0 to 1. When the machine detects "0" as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if "3" is the PSTN access
code, set bit 3 to 1.)