BIT SWITCHES

4.2.6 SG3 SWITCHES

This switches require an optional G3 interface unit.
SG3 Switch 00
No
FUNCTION
0-6 Not used
7
Back to back test
0: Disabled 1: Enabled
FA X
Back-to-Back Connection:
The dc power supplies should be adjusted so that the line current to the NCU is
about 30mA.
SG3 Switch 01
No
FUNCTION
0-3 Not used
4
DIS frame length
0: 10 bytes 1: 4 bytes
5
Not used
6
CED/ANSam transmission
0: Disabled
1: Enabled
7
Not used
A265/A267
CÓPIA NÃO CONTROLADA
Do not change the settings.
Set this bit to 1 when you wish to do a back to
back test.
115 V model: Be sure to connect jumpers JP5
and JP6 on the NCU before doing the test.
220 V model: Be sure to apply dc voltage
between wires L1 and L2 on the NCU.
10 µF
10 µF
10 µF
Do not change the settings.
1: The bytes in the DIS frame after the 4th byte
will not be transmitted (set to 1 if there are
communication problems with PC-based faxes
which cannot receive the extended DIS frames).
Do not change the setting.
Do not change this setting, unless the
communication problem is caused by the
CED/ANSam transmission.
Do not change the setting.
4-60
CÓPIA NÃO CONTROLADA
COMMENTS
1 0µF
FA X
A891M603.WMF
COMMENTS
SM