Gestetner A265 Service Manual page 631

Table of Contents

Advertisement

System Switch 1C
No
FUNCTION
0
PC-Fax Expander option
0: Not installed
1: Installed
1
To omit the PSTN access
code during a PC-Fax
transmission
0: Disabled
1: Enabled
2
Not used
3
Deleting the file when an error
occurs during PC data
storage to the SAF
0: Not cleared
1: Cleared
4
Resolution unit used for PC-
Fax communication
0: mm
1: inches
5-6 Not used
7
PC protocol dump list output
after each PC communication
0: Off
1: On
System Switch 1D - Not used (do not change the settings)
SM
CÓPIA NÃO CONTROLADA
Change this bit to 1 when installing the PC-Fax
Expander.
1: The machine does not dial the PSTN access
code programmed in the PC-Fax application
during PC-Fax memory transmission.
This function becomes effective only when the PC
fax application dials using a Quick/Speed/Group
Dial stored in the fax machine.
The machine will not omit dialing the PSTN
access code when a destination number is
programmed manually.
Do not change the setting.
This function is effective for PC memory
transmission.
0: The pages stored in the SAF will be transmitted
from the machine.
1: All data is cleared when an error occurs.
However, if the SAF memory becomes full during
data storage, the setting of system bit switch 1E
bit 1 determines how data is treated.
This function is also effective for PC printing using
the PCFE option for the fax board.
This bit determines the resolution unit used for PC
fax communication.
This is because the PC fax application cannot
automatically adjust the resolution unit.
This setting is also effective for PC scanning
using the PCFE option for the fax board.
Do not change the settings.
1: This is only used for PC communication
troubleshooting.
Communications between the DIU (PCFE
q
board) and a host PC are logged on the PC
dump list.
If system switch 09 bit 6 is at "1", the list is
only printed if there was an error during the
communication.
PC scan and PC print jobs using the PCFE
q
option for the fax board are printed on the
Journal.
The Data-in LED turns on while data is
q
coming in and going out to the PC.
Be sure to reset this bit to "0" after a test.
4-27
CÓPIA NÃO CONTROLADA
BIT SWITCHES
COMMENTS
A265/A267

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267