Standard White Density Adjustment
This adjusts the standard white density level.
Perform this adjustment in any of the following conditions:
• After replacing the standard white plate.
• After replacing the NVRAM on the BICU board. (If only BICU board is replaced,
this adjustment is not necessary, as the NVRAM from the old BICU is put on the
new BICU.)
• After performing a memory all clear (SP5-801).
Procedure:
1. Place 10 sheets of new A4 sideways (do not use any recycled paper) or A3
paper on the exposure glass and close the platen cover or the ADF.
2. Enter SP 4-908 and select "1: Yes". The standard white density is automatically
adjusted.
SM
CÓPIA NÃO CONTROLADA
COPY ADJUSTMENTS: PRINTING/SCANNING
6-39