AUTO REVERSE DOCUMENT FEEDER INSTALLATION
[D]
[C]
2. Remove the left scale [A] (2 screws).
3. Place the DF exposure glass [B] on the glass holder.
NOTE: When installing the DF exposure glass, make sure that the white point
[C] is on the lower front side of the glass, as shown.
4. Peel off the backing [D] of the double-sided tape attached to the rear side of the
scale guide [E], then install it (2 screws removed in step 2).
5. Install the two stud screws [F].
6. Mount the DF on the copier, then slide the DF to the front.
7. Secure the DF unit with two screws [G].
8. Connect the cable [H] to the copier.
A265/A267
CÓPIA NÃO CONTROLADA
[E]
[B]
A858I103.WMF
CÓPIA NÃO CONTROLADA
[F]
[A]
[F]
[G]
3-18
[G]
[H]
A858I104.WMF