20. Secure the 1st scanner with the scanner wire pins.
21. Install the tension spring [A] to the tension bracket.
22. Tighten the tension bracket [B].
23. Secure the scanner wire pulley [C] (1 Allen screw).
24. Remove the positioning tools [D]. After sliding the scanner to the right and left
several times, re-install the positioning tools to check the scanner wire bracket
and tension bracket again.
25. Reassemble the scanner and do the scanner and printer copy adjustments
(see Copy Adjustments, section 6.8).
SM
CÓPIA NÃO CONTROLADA
6-9
CÓPIA NÃO CONTROLADA
SCANNER UNIT
[A]
[B]
[C]
A267R011.WMF