BIT SWITCHES
SG3 Switch 0B
No
FUNCTION
0
Protocol requirements:
Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
6
Not used
7
Not used
SG3 Switch 0C
No
FUNCTION
0
Pulse dialing method
1
Bit 1 Bit 0 Setting
0
0
0
1
1
0
1
1
2-7 Not used
SG3 Switch 0D - Not used (do not change the settings)
SG3 Switch 0E - Not used (do not change the settings)
SG3 Switch 0F - Not used (do not change the settings)
A265/A267
CÓPIA NÃO CONTROLADA
The machine does not automatically reset these
bits for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
Do not change the setting.
Do not change the setting.
P = Number of pulses sent out, N = Number
dialed.
Normal(P=N)
Oslo (P=10 - N)
Sweden
(N+1)
Not used
Do not change the settings.
CÓPIA NÃO CONTROLADA
COMMENTS
COMMENTS
4-66