Parameter Switch 0A
No.
0
LCN
1
Bit 7 6 5 4 3 2 1 0 Value
2
0 0 0 0 0 0 0 1 1
3
0 0 0 0 0 0 1 0 2
4
0 0 0 0 0 0 1 1 3
5
and so on until
6
1 1 1 1 1 1 1 1 255
7
Parameter Switch 0B
No.
FUNCTION
0
Transport block size
1
Bit 3 2 1 0 Value
2
0 1 1 1 128
3
1 0 0 0 256
1 0 0 1 512
1 0 1 0 1024
1 0 1 1 2048
4-7
Not used
Parameter Switch 0C is not used. Do not change any of the default settings.
Parameter Switch 0D
No.
0
Back-to-back test mode
1
Bit 1 0 Setting
0 0 Off
0 1 Not used
1 0 ISDN L2 test mode (TE mode)
1 1 ISDN L2 test mode (NT mode)
2-7
Not used
SM
CÓPIA NÃO CONTROLADA
FUNCTION
This value must match the value set in the other
terminal. Note that this value must be the same
as the value programmed for the packet size (G4
Parameter Switch 7, bits 0 to 3). Also, the
transport block size is limited by the amount of
memory in the remote terminal.
Do not change the default settings.
FUNCTION
2-13
CÓPIA NÃO CONTROLADA
COMMENTS
Normally, keep at the value of the
LCN at 1.
COMMENTS
COMMENTS
When doing a back-to-back test or
doing a demonstration without a
line simulator, use these bits to set
up one of the machines in TE
mode, and the other in NT mode.
After the test, return both bits to 0.
See "Back-to-back Testing" in the
Troubleshooting section for full
details.
Do not change the default settings.
BIT SWITCHES
A265/A267