Gestetner A265 Service Manual page 45

Table of Contents

Advertisement

Symbol
Name
PCB8
High Voltage Supply
PCB9
Memory (Option)
Lamps
L1
Exposure Lamp
L2
Fusing Lamp
Quenching Lamp
L3
Heaters
Anti-condensation
H1
(Option)
H2
Tray (Option)
Others
TF1
Fusing Thermofuse
TH1
Fusing Thermistor
Laser Synchronization
LSD 1
Detector
CO1
Mechanical Counter
CO2
Key Counter (Option)
SM
CÓPIA NÃO CONTROLADA
ELECTRICAL COMPONENT DESCRIPTIONS
Supplies high voltage to the drum charge roller,
development roller, and transfer roller.
Expands the memory capacity for the copier
features.
Applies high intensity light to the original for
exposure.
Heats the hot roller.
Neutralizes any charge remaining on the drum
surface after cleaning.
Turns on when the main power switch is off to
prevent moisture from forming on the optics.
Turns on when the main power switch is off to
prevent moisture from forming around the paper
trays.
Opens the fusing lamp circuit if the fusing unit
overheats.
Detects the temperature of the hot roller.
Detects the laser beam at the start of the main
scan.
Keeps track of the total number of prints made.
Used for control of authorized use. If this feature is
enabled for copying, copying will be impossible
until it is installed.
1-13
CÓPIA NÃO CONTROLADA
Function
A265/A267

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267

Table of Contents