Gestetner A265 Service Manual page 667

Table of Contents

Advertisement

SG3 Switch 05
No
FUNCTION
0
Initial Tx modem rate
to
Bit 3 2 1 0 Setting (bps)
3
0 0 0 1 2.4 k
0 0 1 0 4.8 k
0 0 1 1 7.2 k
0 1 0 0 9.6 k
0 1 0 1 12.0 k
0 1 1 0 14.4 k
0 1 1 1 16.8 k
1 0 0 0 19.2 k
1 0 0 1 21.6 k
1 0 1 0 24.0 k
1 0 1 1 26.4 k
1 1 0 0 28.8 k
1 1 0 1 31.2 k
1 1 1 0 33.6 k
Other settings - Not used
4
Initial modem type for 9.6 k or
to
7.2 kbps.
5
Bit 5
Bit 4
0
0
0
1
1
0
1
1
6-7 Not used
SG3 Switch 06
No
FUNCTION
0
Initial Rx modem rate
to
Bit 3 2 1 0 Setting (bps)
3
0 0 0 1 2.4 k
0 0 1 0 4.8 k
0 0 1 1 7.2 k
0 1 0 0 9.6 k
0 1 0 1 12.0 k
0 1 1 0 14.4 k
0 1 1 1 16.8 k
1 0 0 0 19.2 k
1 0 0 1 21.6 k
1 0 1 0 24.0 k
1 0 1 1 26.4 k
1 1 0 0 28.8 k
1 1 0 1 31.2 k
1 1 1 0 33.6 k
Other settings - Not used
SM
CÓPIA NÃO CONTROLADA
These bits set the initial starting modem rate for
transmission.
Use the dedicated transmission parameters if you
need to change this for specific receivers.
If a modem rate 14.4 kbps or slower is selected,
V.8 protocol should be disabled manually.
Cross reference
V.8 protocol on/off - SG3 switch 03, bit2
These bits set the initial modem type for 9.6 and
7.2 kbps, if the initial modem rate is set at these
Setting
speeds.
V.29
V.17
Not used
Not used
Do not change the settings.
These bits set the initial starting modem rate for
reception.
Use a lower setting if high speeds pose problems
during reception.
If a modem rate 14.4 kbps or slower is selected,
V.8 protocol should be disabled manually.
Cross reference
V.8 protocol on/off - SG3 switch 03, bit2
4-63
CÓPIA NÃO CONTROLADA
BIT SWITCHES
COMMENTS
COMMENTS
A265/A267

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267

Table of Contents