SERVICE RAM ADDRESSES
680314 to 680319(H) - Modem ROM version (Read only)
680314(H) - Part number (low)
680315(H) - Part number (high)
680316(H) - Control (low)
680317(H) - Control (high)
680318(H) - DSP (low)
680319(H) - DSP (high)
68037E(H) - Time for economy transmission (hour in 24h clock format - BCD)
68037F(H) - Time for economy transmission (minute - BCD)
68039A(H) - Transmission monitor volume 00 - 07(H)
68039B(H) - Reception monitor volume 00 - 07(H)
68039C(H) - On-hook monitor volume 00 - 07(H)
68039D(H) - Dialing monitor volume 00 - 07(H)
68039E(H) - Buzzer volume 00 - 07(H)
6803A1 to 6803A5(H) - Periodic service call parameters
Call interval: 01 through 15 month(s) (BCD)
00: Periodic service call disabled
Date and time of the next call
6803AB to 6803AD(H) - Effective term of automatic service calls
Year: last two digits of the year (BCD)
Month: 01 through 12 (BCD)
Day: 01 through 31 (BCD)
680400 to 6804E0(H) - NCU parameters (Refer to section 4.3 for details)
680DC8 to 680DEF(H) - SC codes NOT for automatic service call
If the fax unit receives a copier engine SC code other than those programmed in
these addresses, the fax unit sends an automatic service call report to the
programmed service station.
Six SC codes have already been programmed at default, as shown in the table
below. Fourteen more SC codes can be programmed, if required (if an address
contains FF(H), a code is not programmed in it).
Program a SC code in four-digit BCD format as shown in the example below.
Example 1: SC code "192"
Address (High) - 01 (BCD)
Address (Low) - 92 (BCD)
Wildcard characters "a" or "A" can be used to specify a series of SC codes.
Example 2: SC code "900 to 999"
Address (High) – 09 (BCD)
Address (Low) – aa or AA (Hex)
A265/A267
CÓPIA NÃO CONTROLADA
Parameters
Day: 01 through 31 (BCD)
Hour: 01 through 24 (BCD)
Parameters
4-94
CÓPIA NÃO CONTROLADA
Address (H)
6803A1
6803A4
6803A5
Address (H)
6803AB
6803AC
6803AD