OPTIONAL UNITS
9. Replace the rear cover and the small cover.
10. Connect the cable to the LINE2 jack, then plug in the machine and turn the
main switch on.
11. Enter service mode and set bit 1 of communication switch 16 to "1". After that
turn the main switch off and on.
12. Print the system parameter list and ensure that "SG3-V34" is listed as an
option.
13. Remind the user to program the items required for PSTN-2 communications.
• RTI for PSTN-2
• CSI for PSTN-2
• Telephone line type
NOTE: The default settings for the user function keys with a G3 unit are as follows.
F1: Start Manual Rx
F2: TEL Mode
F3: Tx Result Display
F4: G3 Line Type Selection
The default settings for the user function keys with G3 and G4 units are as
follows.
F1: Start Manual Rx
F2: TEL Mode
F3: Tx Result Display
F4: Line Type (G3 auto sel./G3-1 dir./G3-2 dir./G4) Selection