Gestetner A265 Service Manual page 212

Table of Contents

Advertisement

SERVICE PROGRAM MODE
Mode No.
Class
Class
1 and 2
3
Main Scan
Magnification
(Engine)
1
2-998*
Main Scan
Magnification
2
(Copy)
Main Scan
Magnification
(Image Rotation)
3
Main Scan
Magnification
(Scanner)
4-008*
1
Leading Edge
Registration
(Scanner)
4-010*
Side-to-side
Registration
(Scanner)
4-011*
A265/A267
CÓPIA NÃO CONTROLADA
Adjusts the magnification in the main scan
direction for the engine.
Use the ! key to toggle between + and -
before entering the value. The specification
is ± 0.5%.
This SP value affects all print modes (copy,
printer, and image rotation). If the main scan
magnification is not correct for copying, also
use SP2-998-2. For image rotation, use
SP2-998-3. See "Replacement and
Adjustment - Copy Adjustment" for details,
Section 6.8.
Adjusts the magnification in the main scan
direction for copying.
This SP affects only copying. It is added to
the value of 2-998-1.
Adjusts the magnification in the main scan
direction for copying with image rotation
mode.
This SP affects only image rotation mode. It
is added to the value of 2-998-1.
Adjusts the magnification in the main scan
direction for scanning.
Use the ! key to toggle between + and -
before entering the value. The specification
is ± 1%. See "Replacement and Adjustment
- Copy Adjustment" for details, Section 6.8.
Adjusts the leading edge registration for
scanning in platen mode.
(–): The image moves in the direction of the
leading edge.
Use the ! key to toggle between + and -
before entering the value. The specification
is 2 ± 1.5 mm. See "Replacement and
Adjustment - Copy Adjustment" for details,
Section 6.8.
Adjusts the side-to-side registration for
scanning in platen mode, Section 6.8.
(–): The image disappears at the left side.
(+): The image appears.
Use the ! key to toggle between + and -
before entering the value. The specification
is 2 ± 1.5 mm. See section 6.8
"Replacement and Adjustment - Copy
Adjustment" for details,
4-24
CÓPIA NÃO CONTROLADA
Function
Settings
-0.5 ~ +0.5
0.1 %/step
0.0 %
-0.5 ~ +0.5
0.1 %/step
0.0 %
-0.5 ~ +0.5
0.1 %/step
0.0 %
–1.0 ~ +1.0
0.1 %/step
0.0%
–5.0 ~ +9.0
0.1 mm/step
0.0 mm
–10.0 ~ +6.0
0.1 mm/step
0.0 mm
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267

Table of Contents