STAMP SOLENOID AND ORIGINAL EXIT SENSOR

3.11 STAMP SOLENOID AND ORIGINAL EXIT SENSOR
[A]
1. Remove the rear cover (1 connector). Also remove the upper cover (the exit
tray).
2. Open the exit guide plate [A]. Next, detach the unit by inserting a screwdriver or
other tool into one of the small openings [B] on either side of the guide plate
holder and pushing firmly.
3. Remove the stamp solenoid [C] (1 screw).
4. Remove the original exit sensor [D] (1 connector).
A265/A267
CÓPIA NÃO CONTROLADA
[B]
A858R509.WMF
8-30
CÓPIA NÃO CONTROLADA
[C]
A858R203.WMF
[D]
SM