Busy tone signal state time tolerance for all ranges, and number of cycles
680433
required for detection (a setting of 4 cycles means that ON-OFF-ON or OFF-
ON-OFF must be detected twice).
Tolerance (±)
Bit
1
0
0
1
1
Bits 7, 6, 5, 4 - number of cycles required for cadence detection
680434
International dial tone frequency
upper limit (high byte)
680435
International dial tone frequency
upper limit (low byte)
International dial tone frequency
680436
lower limit (high byte)
680437
International dial tone frequency
lower limit (low byte)
International dial tone detection
680438
time
680439
International dial tone reset time
(LOW)
68043A
International dial tone reset time
(HIGH)
68043B
International dial tone continuous
tone time
68043C
International dial tone permissible
drop time
68043D
International dial wait interval
(HIGH)
68043E
International dial wait interval
(LOW)
68043F
Country dial tone upper frequency
limit (HIGH)
680440
Country dial tone upper frequency
limit (LOW)
Country dial tone lower frequency
680441
limit (HIGH)
680442
Country dial tone lower frequency
limit (LOW)
SM
CÓPIA NÃO CONTROLADA
Function
0
0
75% Bits 2 and 3 must always
1
50% be kept at 0.
0
25%
1
12.5%
4-71
CÓPIA NÃO CONTROLADA
NCU PARAMETERS
Unit
Hz (BCD)
If both addresses
contain FF(H), tone
detection is disabled.
If both addresses
Hz (BCD)
contain FF(H), tone
detection is disabled.
If 680438 contains FF,
20 ms
the machine pauses for
the pause time (68043D
/ 68043E).
Belgium: See Note 2.
Hz (BCD)
If both addresses
contain FF(H), tone
detection is disabled.
If both addresses
contain FF(H), tone
detection is disabled.
Remarks