SERVICE PROGRAM MODE
No.
008
NIC Data Reset
009
Density Adjustment 1
010
Density Adjustment 2
011
Density Adjustment 3
012
Density Adjustment 4
013
Density Adjustment 5
014
Density Adjustment 6
015
Density Adjustment 7
016
ROM Disk Format
A265/A267
CÓPIA NÃO CONTROLADA
Function
Resets all network interface data
(UP-Network-1 ~ 8)
Press "1" three times to reset.
Adjusts the image density for each
image density level which can be
selected with UT mode (UT-Scan-
Density)
Initializes the flash ROM.
Press "1" three times to initialize.
18-10
CÓPIA NÃO CONTROLADA
Setting
0 ~ 255
1 / step
40
0 ~ 255
1 / step
70
0 ~ 255
1 / step
100
0 ~ 255
1 / step
130
0 ~ 255
1 / step
170
0 ~ 255
1 / step
200
0 ~ 255
1 / step
230
SM