Communication Switch 14
No
FUNCTION
6
Available unit of resolution in
to
which fax messages are
7
received
Bit 7
Bit 6
0
0
0
1
1
0
1
1
Communication Switch 15 - Not used (do not change the settings)
Communication Switch 16
No
FUNCTION
0
Not used
1
Optional G3 unit
0: Not installed
1: Installed
2
Optional ISDN unit
0: Not installed
1: Installed
3-4 Not used
5
Use of the PSTN-2 line
0: Tx or rx
1: Rx only
6
G4 Dual communication
0: Enabled
1: Disabled
7
Not used
SM
CÓPIA NÃO CONTROLADA
For the best performance, do not change the
factory settings.
Unit
The setting determined by these bits is informed
mm
to the transmitting terminal in the pre-message
inch
protocol exchange (in the DIS/NSF frames).
mm and inch
(default)
Not used
Do not change the settings.
Change this bit to 1 when installing the optional
G3 unit.
Change this bit to 1 when installing the optional
ISDN unit.
Do not change the settings.
Change this bit to 1 when the customer requires.
1: The machine uses only one B channel for
communication. This enables a customer to
occupy another B channel for other purposes
such as internet communication.
Do not change the setting.
4-49
CÓPIA NÃO CONTROLADA
BIT SWITCHES
COMMENTS
COMMENTS