ORIGINAL LENGTH, WIDTHSENSOR BOARD AND TRAILING EDGE SENSOR

3.8 ORIGINAL LENGTH, WIDTHSENSOR BOARD AND

TRAILING EDGE SENSOR

[A]
1. Open the original table [A].
2. Remove the upper part of the table (3 screws).
3. Replace the width sensor board [B], length sensor (–1 [C] and –2 [D]) and
trailing edge sensor [E].
NOTE: To ensure proper detection of paper size,
after wiping off the sensor board and
terminal plate with a dry cloth (or cloth with
alcohol), apply silicone grease (KS-660) to
the terminal plate [F].