Gestetner A265 Service Manual page 688

Table of Contents

Advertisement

SERVICE RAM ADDRESSES
6800C1(H) - User parameter switch 01 (SWUSR_01)
Bit 0: Label insertion home position 0: Disabled, 1: Enabled
Bit 1: ID transmission home position 0: Disabled, 1: Enabled
Bit 2: Automatic reduction (tx) home position 0: Disabled, 1: Enabled
Bits 3 and 4: Scanning mode LED home position
(This switch is not printed on the user parameter list.)
Bit 4 3
Setting
0
0
Text
0
1
Text/ Photo
1
0
Photo
1
1
Special Original (See the note below)
Note: The "Special Original" setting is not explained in the Operator's Manual,
because it can be selected only if System Switch 19 – bit 7 is set to "1".
Bit 5: TTI print home position 0: Disabled, 1: Enabled
Bit 6: TTI used for broadcasting; the TTI selected with this switch is used for all
destinations during broadcasting.
0: TTI_1, 1: TTI_2
(This switch is not printed on the user parameter list.)
Note: System Switch 11 bit 3 must be set to "1" to enable this switch.
Bit 7: Settings return to home position after scanning 0: Disabled, 1: Enabled
6800C2(H) - User parameter switch 02 (SWUSR_02)
Bit 0: Forwarding mark printing on forwarded messages 0: Disabled, 1: Enabled
Bit 1: Center mark printing on received copies
(This switch is not printed on the user parameter list.)
0: Disabled, 1: Enabled
Bit 2: Reception time printing
(This switch is not printed on the user parameter list.)
0: Disabled, 1: Enabled
Bit 3: TSI print on received messages 0: Disabled, 1: Enabled
Bit 4: Checkered mark printing
(This switch is not printed on the user parameter list.)
0: Disabled, 1: Enabled
Bit 5: CIL printing (G4) 0: Disabled, 1: Enabled
Bit 6: TID printing (G4) 0: Disabled, 1: Enabled
Bit 7: Not used
6800C3(H) - User parameter switch 03 (SWUSR_03: Automatic report
printout)
Bit 0: Transmission result report (memory transmissions) 0: Off, 1: On
Bit 1: Not used
Bit 2: Memory storage report 0: Off, 1: On
Bit 3: Polling reserve report (polling reception) 0: Off, 1: On
Bit 4: Polling result report (polling reception) 0: Off, 1: On
Bit 5: Transmission result report (immediate transmissions) 0: Off, 1: On
Bit 6: Polling clear report 0: Off, 1: On
Bit 7: Journal
0: Off, 1: On
A265/A267
CÓPIA NÃO CONTROLADA
4-84
CÓPIA NÃO CONTROLADA
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A267

Table of Contents