[When the pipe is extended to left and taken out from the rear center]
(Drain pipe relocation procedure)
1. Remove the drain pipe.
¡ Loosen the spring clamp to
remove.
¡ When arranging the pipe through a hole opened at the center, open the
knockout hole using nippers, etc.
(4) Installation of indoor unit
(a)
Hang the upper portion of the unit rear cover on the mounting board,
and then magnet on the lower unit portion will pull to fix the unit.
(b)
Be sure not to leave any trap on the drain pipe.
Declining slope

2.5.3 Installation of outdoor unit

(1) Installation of outdoor unit
(a)
Make sure that sufficient space for installation and service is secured.
(b)
Fix the leg sections of the unit on a firm base which will not play.
Attach cushion pads, etc. between the unit and the mounting fixtures not to transmit vibration to the building.
(c)
Attach a drain elbow, etc. under the drain port of the bottom plate to guide drain water. (Drain elbow should not be used
where days when temperature drops below 0˚C continue for several days. Draining may be disturbed by frozen water.)
(d)
When installing the unit at a higher place or where it could be toppled with strong winds, secure the unit firmly with
foundation bolts, wire, etc.
(2) Connection of indoor and outdoor connecting wiring
(a)
Connect the wiring according to the number of the indoor terminal block. (Mis-wiring may cause the burning damage, and
make sure to connect correctly.)
2. Remove the drain cap.
3. Insert the drain cap.
¡ Remove by hand or use
¡ Securely insert the drain cap
cutting pliers, etc.
Note: If it is inserted insufficiently,
Trap
Inverted slipe
Wiring clamp
Terminal block
Earth terminal
Interconnecting wire
4. Connect the drain pipe.
¡ Loosen the spring clamp and
removed in the step 2.
securely insert the drain pipe.
Note: If it is inserted insufficiently,
water leakage could result.
water leakage could result.
Note (1) It is designed to collect moisture
accumulated on the rear face in the
drain pan. Be sure not to accommodate
the power cable, etc. above the chute.
type
1 BROWN
2 BLUE
3 BLACK
4 GREEN
YELLOW
GREEN
SRK-H
Chute
Wall
Pipe accommodation space
Slighty push
Mounting
block
Wall
Cooling only
Heat pump
type
81