SRK-GZ
(3) Flap control
Control the flap by AIRFLOW button on the wireless remote control.
(a) Natural flow (AUTO)
The flap will be automatically set to the angle of air flow best to operation.
(i)
Starting time of operation
Models SRK25GZ-L1, 35GZ-L1
In case of cooling
s
and dry operation
Stops at the level position for
one minute.
¡ The flap operation as shown above will be
repeated.
Model SRK502Z-L
During cooling and
s
dry operation
Stops for approximately
10 seconds in the
horizontal position.
Thick line
Thin line
(ii) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Memory flap (Excepted SRK 25 model)
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is
started.
¡
Recommendable stopping angle of the flap
COOL•DRY
(c) Swing flap
Flap moves in upward and downward directions continuously.
18
t
Sway operation
t
Stops for approximately
13 seconds in this
: Rapid movement
position.
: Slow movement
Horizontal
blowing
In case of heating
s
operation
Sway operation
Flap stops 3'50" on
this position.
¡ When the room temperature controller (ther-
mostat) is activated, horizontal blowing is ap-
plied to prevent cool wind from blowing out.
During heating
s
t
operation
Thick line
Thin line
HEAT
Slant forward
blowing
t
: Rapid movement
: Slow movement