Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 280

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

FDT ( N ) -H
Model FDT408HES-A
Item
(1)
Nominal cooling capacity
Nominal heating capacity
(1)
Power source
Cooling input
Runningcurrent (Cooling)
Power factor (Cooling)
Heating input
Running current (Heating)
Power factor (Heating)
Cooling input
Running current (Cooling)
Power factor (Cooling)
Inrush current (L.R.A)
(4)
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigarant oil
Defrost control
High pressure control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow (Standard)
Fresh air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
Cooling
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 380/415V 50Hz and 380V 60Hz respectively.
(4) Indicates the value at mild mode.
278
Model
ISO-T1
W
ISO-T3
ISO-T1
W
kW
A
%
kW
A
%
kW
A
%
A
dB(A)
mm
kg
kW
Louver fins & inner grooved tubing
kg
r
W
CMM
Rubber sleeve (for fan motor)
W
Internal thermostat for fan motor.
mm
(in)
Item
Indoor air temperature
DB
27˚C
20˚C
29˚C
FDT408HES-A
FDT408-A
10200/11300
9900
10500/11600
3 Phase, 380-415V 50Hz or 380V 50Hz/415V 50Hz, 380V 60Hz
3.78/3.78/4.65
7.5/7.5/8.8
77/70/80
3.48/3.48/4.28
7.2/7.2/8.5
73/67/77
5.15
9.5
82
45
Hi:48 Lo:40
Unit 320 × 840 × 840
Panel 30 × 950 × 950
34 (Unit:28 Panel:6)
Capillary tube
R22
Holding charged
IC controlled de-icer
High pressure regulator valve
Turbo fan × 1
80 × 1
Line starting
Hi: 26 Lo: 19
Available
Long life filter ×1(washable)
Wired remote control switch
(Optional : RCD-H-S-E)
Thermostat by electronics
Frost protection thermostat.
Liquid line: φ9.52 (3/8") Gas line: φ19.05 (3/4")
Flare piping
(Connectable with VP25)
Neccessary (both Liquid & Gas lines)
Mounting kit. Drain hose
Decorative Panel
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
19˚C
46˚C
FDC406HES3
57
1250 × 950 × 340
86
RC5547ESE1 × 1
2.61
Line starting
Slitted fins & bare tubing
1.6 [Pre-charged up to the piping length of 5m]
1.63 (SUNISO 3GS)
Propeller fan × 2
60 × 2
Line starting
100/110
Rubber mount (for compressor)
40 (Crank case heater)
– (Indoor unit side)
Internal protector for compressor.
Internal thermostat for fan motor.
Internal pressure relief valve for compressor.
Standards
WB
24˚C
ISO-T1, JIS B8616
6˚C
24˚C
ISO-T3, SASO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all

Table of Contents