Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 69

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

(2) Back-up Switch
When the remote controller batteries become weak, or if the remote controller is lost or malfunctioning, this switch may be used to
turn the unit on and off.
(a) Operation
Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
sensor), whether to go into the cooling, thermal dry or heating modes.
Function
Room temperature
setting
Operation mode
Cooling
About 26ºC
Thermal dry
About 25ºC
Heating
About 25ºC
On operating in automatic operation mode by back-up switch, functions show in the above table are not altered, white, the other micro-
computer control functions remain effective.
• 32, 40 models
ON/OFF
(3) AUTOMATIC operation
(a) When starting operation after more than 1 hour since operation stops
(Operation stop button ON or ON-Timer), this system operates indoor fan with Lo for 20 seconds checks room temperature
and allowing decision of operating mode automatically.
Operation Mode
Note (1)
Operating Mode is not altered due to change of room temperature.
When intended to change operating mode, switch operation change over dial to the intended mode.
(b) Established temperature (operate by the established temperature button on remote controller).
-6
Cooling
20
Thermal dry
19
Heating
19
(c) When switching to automatic operation during "Heating" "Cooling" "Dry" or when restarting with in 1 hour
after stopping with automatic operation mode, the former operating mode is selected. (In this case, 20 seconds Lo operation
of indoor fan is not performed). When the previous mode is in "FAN", operation mode is to be set by the above mentioned
chart.
Fan speed
Auto
Natural flow
Back-up switch
Room temperature<21ºC
Heating
Wireless remote control signal (Indication)
-5
-4
-3
-2
21
22
23
24
20
21
22
23
20
21
22
23
Flap
Timer switch
Continuous
• 50, 56 models
ON/OFF
Back-up switch
21ºC Room temperature<26ºC
Dry
±0
-1
+1
+2
25
26
27
28
24
25
26
27
24
25
26
27
SRK-H
26ºC Room temperature
Cooling
+3
+4
+5
+6
29
30
31
32
28
29
30
31
28
29
30
31