Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 58

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

SRK-H
Model SRK501HENF-L (Indoor unit)
SRC501HENF-L (Outdoor unit)
Item
(1)
Cooling capacity
(1)
Heating capacity
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Noise level
(5)
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(4)
Refrigerant
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
(Cooling)
(Heating)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application Minimum: 198V Maximum: 264V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per
meter.)
(5) Expressed in sound pressure level.
56
Model
W
W
kW
A
kW
A
A
dB(A)
Cooling: 44/44
mm
kg
kW
kg
R
W
CMM
Polypropylene net (washable) x 2
Wireless–Remote controller
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
mm(in)
Item
Indoor air temperature
DB
27ºC
20ºC
SRK501HENF–L
4500/4500
5700/5800
1 Phase, 220/240V, 50Hz
1.78/1.88
8.4/8.2
1.76/1.89
8.5/8.3
39/42
2.53/2.39
Heating: 45/45
275‚790‚189
Ivory white
9
Louver fins & bare tubing
Capillary tubes
R22 1.28
0.7 (BARREL FREEZE 32SAM)
MC control
Tangential fan x 1
23
11/11
12/12
MC. Thermostat
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Flare connecting
Liquid line: 0.4m
Gas line: 0.35m
Necessary (Both sides)
Connectable
2.5m (3 cores with Earth)
1.5mm
2
x 5 cores (With Earth)
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
SRC501HENF–L
Cooling: 50/51
Heating: 53/54
615‚850‚290 + 30
Polar white
53
RM5523GNE4 (Rotary type) x 1
1.7
Line starting
Propeller fan x 1
40
34/34
34/34
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Standards
WB
24ºC
JIS C9612, ISO-T1
6ºC
JIS C9612, ISO-T1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all

Table of Contents