Models FDRJ112HKXE2, 140HKXE2
Item
Air inlet panel
Panel model (Option)
1
Nominal cooling capacity*
2
Nominal heating capacity*
Power source
Noise level
Exterior dimensions
Height
Width
Depth
Net weight
Refrigerant equipment
Heat exchanger
Refrigerant control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow(Standard)
Available static pressure
( at Me)
Fresh air intake
Air filter Q'ty
Shock & vibration absorber
Insulation (noise & heat)
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Outdoor units to be combined
Notes
(1)The data are measured at the following conditions.
Item
Operation
1
Cooling*
2
Heating*
(2)This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616"UNITARY AIR-CONDITIONERS"
(3)Canvas panel is used in combination with following canvas duct
Canvas duct: HA01484
(4)The number "2",following the type of each model,represents"CE-marked model"especially for European Union, and for European nations which
require CE marking.
(5)Add the canvas duct lenght to the unit height for the canvas type.
Models
FDRJ112HKXE2
Silent panel
R-PNLS-46W-E
W
W
dB(A)
Hi: 45 Me: 42 Lo: 38
Unit:406
1370 635
mm
Panel:10
1660 750
Unit:50
kg
Panel:9
W
45 1,
CMM
Hi: 28 Me: 25 Lo: 22
Pa(mmAq)
mm(in)
Indoor air temperature
DB
WB
27
19
20
(4)
Canvas panel
Silent panel
R-PNLC-46W-E
R-PNLS-46W-E
11200
12500
1 Phase 220/240V 50Hz
Hi: 46 Me: 43 Lo: 39
Hi: 46 Me: 43 Lo: 39
Unit:(350+α)
1370 635
Unit:406
Panel:10
1484 585
Panel:10
Unit:50
Panel:7
Louver fins & inner grooved tubing
Electronic Expansion Valve +Capillary tube
Centrifugal fan 3
90 1
Line starting
Standard:50(5.0), Hi speed:80(8.0)
Side or back
Long life filter
2(Washable)
Rubber sleeve(for fan motor)
Polyurethane foam
Remote control switch (Optional:RCD-HKX-E2)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat
Liquid line: 9.52(3/8"),Gas line: 19.05(3/4")
Flare piping
Connectable with VP25
Necessary (both Liquid & Gas lines)
Mounting kit
Silent panel, Canvas panel, Canvas duct
FDCP2001HKXRE2, 2501HKXRE2
Outdoor air temperature
DB
WB
35
24
7
6
FDC-HKXR
(4)
FDRJ140HKXE2
Canvas panel
R-PNLC-46W-E
14000
16000
Hi: 47 Me: 44 Lo: 40
1370 635
Unit:(350+α)
1370 635
1660 750
Panel:10
1484
Unit:52
Unit:52
Panel:9
Panel:7
50 1,
100 1
Hi: 34 Me: 31 Lo: 27
Standards
ISO-T1,JIS B8616
585
951