Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 538

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

FDR-H
Model FDR308HEN-A
Item
Decorative panel
Panel model (Option)
(1)
Nominal cooling capacity
(1)
Nominal heating capacity
Power source
Cooling input
Running current (Cooling)
Power factor (Cooling)
Heating input
Running current (Heating)
Power factor (Heating)
Inrush current
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
High pressure control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow (Standard)
Available static pressure
Fresh air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 220/240V 50Hz.
(4) Canvas panel is used in combination with following canvas duct. Canvas duct: HA01503
(5) Main unit height of canvas specification type is higher than the other type for canvas duct portion.
536
Model
Silent panel
R-PNLS-36W-E
W
W
kW
A
%
kW
A
%
A
dB(A)
Hi: 44 Lo: 38
Unit: 355 × 950 × 635
mm
Panel: 10 × 1240 × 750
kg
Unit: 35 Panel: 8
kW
Louver fines & inner grooved tubing
kg
r
Multiblade centrifugal fan × 2
W
CMM
Pa
Standard: 45 (4.5) High: 80 (8.0)
(mmAq)
Polypropylene net × 2 (washable)
Rubber sleeve (for fan motor)
W
Internal thermostat for fan motor.
Frost protection thermostat.
mm
(in)
Item
Indoor air temperature
DB
27˚C
20˚C
FDR308HEN-A
FDR308-A
Canvas panel
R-PNLC-36W-E
7100
7300
1 Phase, 220/240V, 50Hz
3.11/3.15
15.7/16.4
90/80
2.86/2.90
14.6/15.3
89/79
89
Hi: 45 Lo: 39
Unit: (299+α) × 950 × 635
Panel: 10 × 1064 × 585
Unit: 35 Panel: 6
Capillary tube
R22
Holding charged
IC controlled de-icer
High pressure regulator valve
100 × 1
Line starting
Hi: 20 Lo: 15
Available
Wired remote control switch
(Optional : RCD-H-E)
Thermostat by electronics
Liquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")
Flare piping
(Connectable with VP25)
Necessary (both Liquid & Gas lines)
Mounting kit, Drain hose
Decorative Panel
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
FDC306HEN3
_
_
56
844 × 950 × 340
69
RC5532ENE1 × 1
2.24
Line starting
Slitted fines & bare tubing
1.3 [Pre-charged up to the piping length of 5m]
1.63 (SUNISO 3GS)
Propeller fan × 1
60 × 1
54
Rubber mount (for compressor)
40 (Crank case heater)
— (Indoor unit side)
Internal protector for compressor.
Internal thermostat for fan motor.
Internal Pressure relief valve for compressor.
Standards
WB
24˚C
ISO-T1, JIS B8616
6˚C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all