Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 78

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

SRK-H
(14) High power operation (Remote controller "HI POWER" button on) [50, 56 model only]
The indoor unit fan rotates at speed 4 for 15 minutes, and carries out continuous cooling and heating.
(15) Economy operation (Remote controller "ECONO" button on) [50, 56 model only]
(a) Cooling economy operation
The indoor unit fan operates 2ºC higher than the set temperature at speed 1.
(b) Thermal dry economy operation
Thermal dry operation carried out at 2ºC higher than the set temperature.
(c) Heating economy operation
The indoor unit fan operates 2ºC lower than the set temperature at speed 2.
(16) Self diagnosis function
When something abnormal happens on the outdoor unit, indoor unit fan motor and each sensor (heat exchanger, room tempera-
ture,) it will be indicated by flashing lamps.
(a) Abnormality of outdoor unit: TIMER lamp will flashing when 5 minutes after it has been operated with the compres-
(b) Abnormality of indoor fan motor: The indoor fan motor revolves at a rate under 300 rpm for 30 seconds or longer, the
(c) Abnormality of heat exchanger thermistor: RUN lamp will flashing when the input temperature of the heat exchanger
(d) Abnormality room temperature thermistor: RUN lamp will flashing when the input temperature of the room tem-
Note (1)
If the above abnormalities happen concurrently, the lamp will flashing in the order of item number (a) through (d) above.
76
sor ON (52ºC ON) the temperature on heat exchanger thermistor will not go below 25ºC
for more than 20 minutes for cooling and will not go over 30ºC for more than 20 minutes
for heating.
(The compressor will stop when cooling more than 20 minutes after flashing of the lamp,
or heating above 25ºC abe below 30ºC.)
RUN lamp will flash.
thermistor measures less than –20ºC for more than 3 seconds with the
air-conditioner "OFF". (will not flashing during operation)
perature thermistor measures less than –20ºC for more than 3 seconds
with the air-conditioner "OFF". (will not flashing during operation)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all

Table of Contents