Model SRK561HENF-L (Indoor unit)
SRC561HENF-L (Outdoor unit)
Item
(1)
Cooling capacity
(1)
Heating capacity
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Noise level
(5)
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(4)
Refrigerant
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
(Cooling)
(Heating)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per
meter.)
(5) Expressed in sound pressure level.
Model
SRK561HENF–L
W
W
kW
A
kW
A
A
dB(A)
Cooling: 45/45
mm
275‚790‚189
Ivory white
kg
9
kW
kg
R
Tangential fan x 1
W
23
12/12
CMM
13/13
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
mm(in)
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Liquid line: 0.4m
Gas line: 0.35m
Indoor air temperature
DB
WB
27ºC
19ºC
20ºC
Minimum: 198V Maximum: 264V
5000/5000
6200/6300
1 Phase, 220/240V, 50Hz
2.08/2.18
10.2/9.53
2.02/2.15
10.5/9.95
44/48
2.40/2.29
Heating: 46/46
Cooling: 53/54 Heating: 54/56
615‚850‚290 + 30
RM5526GNE4 (Rotary type) x 1
Louver fins & bare tubing
Capillary tubes
R22 1.35
0.7 (BARREL FREEZE 32SAM)
MC control
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Flare connecting
Necessary (Both sides)
Connectable
2.5m (3 cores with Earth)
1.5mm
2
x 5 cores (With Earth)
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
DB
WB
35ºC
24ºC
7ºC
6ºC
SRK-H
SRC561HENF–L
Polar white
53
1.9
Line starting
Propeller fan x 1
40
34/34
34/34
Standards
JIS C9612, ISO-T1
JIS C9612, ISO-T1
57