Mitsubishi Heavy Industries SRK25GZ-L1 Handbook page 755

2000 air conditioning & heat pump machinery handbook
Table of Contents

Advertisement

FDTS Series
Models
Item
Power input (kW)
Running current (A)
FDR, FDUM Series
Models
Item
Power input (kW)
Running current (A)
FDE Series
Models
Item
Power input (kW)
Running current (A)
FDK, FDFL, FDFU Series
Models
Item
Power input (kW)
Running current (A)
Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 "UNITARY AIR-CONDITIONERS"
(2) The values shown in the above table are common to both cooling and heating operations.
(c) Calculation of total operation characteristics
Since the operation characteristics of series Multi-KX depend on combination of indoor unit, calculate the total operation characteristics
of the system by using the formulas below according to specifications of each indoor unit or outdoor unit.
1) Total power input
Total power input (kW) = Power input of outdoor unit + ∑ (Power input of indoor unit)
2) Total running current
Total running current (A) = Running current of outdoor unit + [∑ (Running current) × 2/3]
3) Total power factor
Total power factor (%) = [Total power input (W) / √
Total operation characteristics = Operation characteristic value of outdoor unit + Operation characteristic value of indoor unit
[Example]
(Conditions)
FDTS Series
22
28
36
0.07/0.08
0.33/0.36
22
28, 36
45
0.09/0.11
0.11/0.13
0.41/0.46
0.51/0.56
FDE Series
36
45
56
0.10/0.11
0.43/0.46
FDK Series
22
28
36
0.05/0.06
0.26/0.28
3 × Total running current (A) × Power source] × 100
Operation Voltage ········Indoor unit: 220 V, 50 Hz
Outdoor unit: 380 V, 50 Hz
Operation mode ··········· Cooling and Heating
Unit·······························Outdoor unit: FDCJ224HKXE2B × 1 unit
Indoor unit: FDTJ71HKXE2 × 2 units
(220 V/240 V)
45
71
0.09/0.11
0.12/0.15
0.43/0.46
0.58/0.63
FDR, FDUM Series
56
71
0.14/0.16
0.15/0.17
0.63/0.67
0.68/0.71
(220 V/240 V)
71
112
0.12/0.15
0.20/0.24
0.58/0.63
0.90/0.98
45
56
71
0.06/0.07
0.08/0.09
0.09/0.11
0.31/0.33
0.36/0.39
0.41/0.48
FDTJ45HKXE2 × 2 units
FDC-HKX
(220 V/240 V)
90
112
140
0.16/0.19
0.24/0.28
0.28/0.32
0.73/0.79
1.07/1.17
1.28/1.32
140
0.24/0.29
1.10/1.20
(220 V/240 V)
FDFL, FDFU Series
28
45, 56
71
0.09/0.10
0.09/0.10
0.09/0.10
0.41/0.42
0.40/0.41
0.40/0.41
753

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk35gz-l1Srk502z-l1Srk502z-lSrk328henf-l2Srk408henf-l2Srk501henf-l ... Show all

Table of Contents